Canada
270 Sherman Avenue N.
Hamilton, ON L8L 6N5
Phone: (905) 545 2003• Fax: (905) 545 4248
United States
1925 Pine Avenue
Niagara Falls, NY 14301
Phone: (716) 285-0418 • Fax: (716) 282-2937
 
Email: sales@nova-gas.com or websales@nova-gas.com
All Categories > By Primary Gas to be Measured > Oxygen Analyzers (O2) > Portable Oxygen in Ambient Air Monitor (O2) > Item # Model 600  


Item # Model 600, Portable Multigas Ambient Air Analyzer - 600 Series


For ambient air or confined space monitoring for up to any four choices of O2, CO2, NO, NO2, CO, LEL combustibles, temperature, and % RH. Single gas versions are also available for H2S, SO2, Cl2, HCL & NH3.

 







Specifications  · Applications  · Features  · Options  · Calibration  · Unique Applications

Specifications

Method of Detection

O2, CO, SO2, NO, NO2, HCL, CL2, NH3 and H2S by electrochemical sensor, % RH by capacitive polymer, CO2 by infrared sensor, LEL by catalytic sensor

Ranges Available

0-100 PPM NO
0-100% RH

0-20 PPM Cl2

0-20 PPM H2S

0-20 PPM NH3

0-20 PPM NO2

0-200 PPM CO

0-200 PPM H2

0-25.0% O2

0-50 PPM SO2

0-50°C Temp.

0-5000 PPM CO2

Resolution

0.1% on % O2, 1 PPM on PPM gases

Accuracy & Repeatability

±2% of full scale

Drift

Less than 1% of full scale or 2 PPM per 8 hours, whichever is greater, with constant ambient temperature

Response Time (T-90)

Varies with individual sensor but generally under 2 minutes for full reading

Ambient Temperature Range

40° to 120°F (4° to 49°C) ºC

Linearity

Better than ±2% of full scale

Size & Weight

15" W x 7" H x 12" D @ 14 lbs. (375 x 175 x 305 mm @ 6.4 kg)

Power

115 VAC, 60 Hz for recharging
220 VAC, 50 Hz

Output Options

4-20 mA

Alarms

Optional audible & visual alarms

Gases Measured

0) NH3 - 0-20 PPM
1) O2 - 0-25.0%

2) CO - 0-200 PPM

3) CO2 - 0-5000 PPM

4) LEL Combustibles

5) H2S - 0-20 PPM

6) SO2 - 0-50 PPM

7) NO - 0-100 PPM

8) NO2 - 0-20 PPM

9) Cl2 - 0-20 PPM


Applications
For ambient air or confined space monitoring for up to any four choices of O2, CO2, NO, NO2, CO, LEL combustibles, temperature, and % RH. Single gas versions are also available for H2S, SO2, Cl2, HCL & NH3.



Features
  • Rugged design that is easy to operate and maintain
  • Fast warm-up and response
  • Separate electrochemical sensor for each gas
  • Sensitive infrared detector for CO2
  • Catalytic sensor for LEL combustibles
  • Capacitive polymer sensor for % RH
  • Digital meter readout with backlight
  • Built-in sampling pump, flow meter, filter and 12 ft. sampling hose
  • Rechargeable battery
  • Rugged suitcase (K) style case




Options
  • Audible and visual alarms
  • Built-in printer
  • Built-in data logging




Calibration
  • Nitrogen (N2) for zero
  • Analyzed gas cylinders for span




Unique Applications
The Nova 600 Series is intended as a breathing air monitor, and is not marketed as an analytical instrument such as might be used in environmental applications and laboratories. Warmup time is approximately four minutes. The operating humidity range for this series of analyzers is 0-90% RH non-condensing.




Print Back