Item # Model 412N4N7, Model 412N4N7 Paramagnetic Oxygen Analyzer, ex-proof sensor housing with NEMA4 wall-mount control cabinet (two separate enclosures)
|
|
|
|
The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series. Depending on application, some light-duty sample conditioning features may be available.
For clean process measurements, percent-level O2 gas. This sensor utilizes a paramagnetic measuring cell and powerful selenium cobalt magnet assembly to make use of the principle that oxygen is drawn into a magnetic field, thereby offering a method of detection that is very specific to oxygen. Sample dew point should be at least 5°C (9°F) below lowest sample temperature.
All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinets: NEMA7 Explosion-proof sensor cabinet for Class1 Div1 areas, with NEMA4 wall-mount control cabinet for non-hazardous areas (two separate cabinets)
|
|
|
|
|
Method of Detection
|
|
Magneto-dynamic paramagnetic O2 cell
|
|
Ranges Available
|
|
With back-pressure control: 1.00, 2.00, 5.00, 25.00, 100.0 % O2 Without back-pressure control: 1.0, 2.0, 5.0 % O2
|
|
Accuracy & Repeatability
|
|
±0.5% of full scale or 0.05%, whichever is greater
|
|
Drift
|
|
±0.2% of full scale per month
|
|
Ambient Temperature Range
|
|
40 to 104°F (4 to 40°C)
|
|
Linearity
|
|
±0.5% of full scale or 0.05%, whichever is greater
|
|
Size & Weight
|
|
EX-PROOF: 61H x 33W x 31H cm (24"H x 13"W x 12"D) NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D)
|
|
Output Options
|
|
4-20 mA into 500 ohms non-isolated standard
|
|
Alarms
|
|
High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
|
|
Analyzer Type
|
|
O2 Analyzer
|
|
Hazardous Area Rating Options
|
|
Control Cabinet - General Purpose, Non-Hazardous Detector Cabinet - NEMA7 Class 1 Division 1 Groups BCD
|
|
|
|
|
For continuous analysis of oxygen (O2) using a paramagnetic type detector, in clean dry process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications.
|
|
|
|
- Highest accuracy O2 analyzer, very stable
- Fast response (T90 - 4 to 5 seconds) and bright digital readout
- Linear over entire 0-100% range
- Microprocessor control
- Non-consumable O2 detector, no periodic replacement required
- Built in sample pump or pressure regulator, and 4-20mA outputs
- To improve accuracy, detector can optionally be temperature-controlled and
compensated for changes in barometric pressure in the vented sample
|
|
|
|
- Hi/Low gas, low flow, and diagnostic alarms available
- Isolated analog, RS485 outputs available
|
|
|
|
- Nitrogen for zero
- Air or analyzed calibration gas for span
|
|
|
|
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.
|
|
|
|
|
|
|
|
|
|
|
|