Item # Model 510D/P, Model 510 D or P, Oxygen Deficiency Alarm Monitor, diffusion or pump, Wall Mounted
|
|
|
|
The Nova 510 Series oxygen deficiency or excess alarm monitors are designed as an O2 'watchdog' against accidental displacement of ambient air in a confined space by inert gases, or by a buildup of too much O2 from an O2 leak in the room. The monitors all utilize a long life electrochemical O2 sensor. Actual O2 concentration is shown on a digital meter on the front panel.
Optional dual level alarm with local indication, relay contacts, and audible alert available. Alarm set points are pre-set at Nova but are field adjustable if desired. Flashing strobe light and upgraded cabinets also available.
Models:
- 510D - Diffusion sensor, no pump and no moving parts; excellent for O2 monitoring in immediate local environment
- 510P - Pumped sample version; pump pulls air sample from wider area or from another isolated environment, such as from a closed room
|
|
|
|
|
|
|
To monitor confined spaces, labs, control rooms, tunnels, oxygen plants, etc. for oxygen (O2) deficiency or excess.
|
|
|
|
- Best value high accuracy O2 monitor
- Bright digital readout
- 4 to 5 year life electrochemical O2 sensor
- Available with pumped or diffusion-style sampling
- Easy to use and calibrate
- Fast response (T90 - 6 to 8 seconds)
- NEMA 12 dust tight enclosure
- 4-20mA recorder output
|
|
|
|
- Two levels of O2 alarm with local indication, relay contacts, and audible alarm with 'Acknowledge' button
- Low flow alarm on pumped sample models
- NEMA 4 weather-resistant enclosure
- Strobe light for alarm indication
- 510D - Diffusion sensor, no pump and no moving parts; excellent for O2 monitoring in immediate local environment
- 510P - Pumped sample version; pump pulls air sample from wider area or from another isolated environment, such as from a closed room
|
|
|
|
- Although calibration of zero should not be necessary, it can be checked on nitrogen
- Analyzed gas or outside ambient air with 20.9% O2 for span
|
|
|
|
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs.
|
|
|
|
|
|
|
|
|
|
|
|
|
|