Canada
270 Sherman Avenue N.
Hamilton, ON L8L 6N5
Phone: (905) 545 2003• Fax: (905) 545 4248
United States
1925 Pine Avenue
Niagara Falls, NY 14301
Phone: (716) 285-0418 • Fax: (716) 282-2937
 
Email: sales@nova-gas.com or websales@nova-gas.com
All Categories > By Industry or Application Specific Product Lines > Indoor Air Quality & Personnel Safety > Continuous Ethylene (C2H4) Alarm Monitors - 596 Series > Item # Model 596D  


Item # Model 596D, Continuous Ethylene (C2H4) Alarm Monitor, diffusion sensor


Designed to monitor and alarm for ethylene (C2H4) levels in ambient air near agricultural sites, food & fruit storage, and controlled atmosphere storage, etc. The ethylene sensor is of the disposable electrochemical type with an expected life of between 3-4 years. The sensor needs no warm up time and is ready to go as soon as the monitor is turned on.

Model 595D has one built-in diffusion-style sensor.



Image




Specifications  · Applications  · Features  · Options  · Calibration  · Unique Applications

Specifications

Method of Detection

Disposable electrochemical cell

Ranges Available

0-20 PPM standard

Resolution

1 PPM

Accuracy & Repeatability

±1% of full scale or 1 PPM, whichever is higher

Drift

Less than 1% of full scale or 2 PPM per week, whichever is greater

Response Time (T-90)

Less than 15 seconds to 90% step change

Ambient Temperature Range

32 to 120°F (0 to 40°C), may be operated at lower temperature with auxiliary heater

Linearity

±1% of full scale or 1 PPM, which ever is higher

Size & Weight

14" H x 12" W x 8" D (35.6 x 30.5 x 20.3 cm) @ 18 lbs. (8.2 kg)

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

0-1 VDC
4-20 mA


Applications
    Designed to monitor and alarm for ethylene (C2H4) levels in ambient air near industrial sites, manufacturing facilities, combustion processes, etc.




Features
  • Standard electrochemical cell
  • Instant warm-up, no wait
  • Bright digital readout - no reading interpretation errors.
  • Easy use and calibrate
  • Easy to maintain modular layout
  • 4-20mA output signal for recording
  • NEMA 12 fiberglass enclosure is standard




Options
  • 'Fail Safe' alarms available
  • Strobe light
  • NEMA 4 or 4X enclosures
  • Cold weather package for operation to -5°F (-20°C)




Calibration

  • Ambient air for O2 and to zero all other gases
  • Analyzed calibration gas with representative concentrations for span of all other gases



Unique Applications
    All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.




Print Back