Item # Model 460N4, Model 460N4 Sulfur Dioxide Analyzer, Wall Mounted NEMA4 (IP65) Enclosure Rating
|
|
|
|
The Nova FLEXI-NOVA Series Platform has been designed for continuous gas measurements in applications and environments that are less intensive. Lab work, research, clean processes, pre-treated / pre-cleaned produced gases, and others, may benefit from the FLEXI-NOVA series.
Depending on application, some light-duty sample conditioning features may be available. For clean process measurements, percent and ppm-level SO2 gas. All sensors / detectors are temperature-controlled or temperature-compensated for maximum analytical stability. Easy calibration using touch-screen controls. Serial Output Package allows connection & data-logging to personal computers via a choice of USB / RS-232 / RS-485.
Cabinet: NEMA 4 Weather-proof steel cabinet with window
|
|
|
|
|
Method of Detection
|
|
Low range PPM SO2 by electrochemical sensor Microprocessor based single cell NDIR
|
|
Ranges Available
|
|
460 - 0-1, 0-5, 0-10 % SO2 460L - 0-2000, 0-3000, 0-5000, PPM SO2
|
|
Resolution
|
|
0.1% SO2 on % versions, 10 PPM SO2 on PPM versions
|
|
Accuracy & Repeatability
|
|
1% of full scale
|
|
Drift
|
|
Less than 2% of full scale per month
|
|
Response Time (T-90)
|
|
15-30 seconds to T-90
|
|
Ambient Temperature Range
|
|
40 to 104°F (4 to 40°C). Optional: up to 130°F (55°C) with cabinet cooler
|
|
Linearity
|
|
±1% of full scale
|
|
Size & Weight
|
|
NEMA 4: 51H x 41W x 26D cm (20"H x 16"W x 10"D) RACK MOUNT: 22H x 48W x 47D cm (8.7"H x 19"W x 16"D)
|
|
Power
|
|
115 VAC, 60 Hz 220 VAC, 50 Hz
|
|
Output Options
|
|
4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, serial outputs
|
|
Alarms
|
|
High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm
|
|
Analyzer Type
|
|
SO2 Analyzer
|
|
Hazardous Area Rating Options
|
|
General Purpose, Non-Hazardous
|
|
|
|
|
For continuous analysis of sulfur dioxide (SO2) in process gas streams using an infrared detector. Percent and PPM levels available as Models 460 & 460L respectively.
|
|
|
|
- Percent (460) or PPM (460L) SO2 by infrared detector
- Low range PPM (461) SO2 by electrochemical sensor
- NDIR detector is sensitive, reliable, and non-depleting
- Electrochemical sensor is easy to replace when needed
- Touch-screen display for gas readings
- Easy-to-maintain modular layout
- Sensor is temperature controlled for maximum stability
- Built-in sample pump, flowmeter, and filters
- 4-20mA non-isolated recorder output
|
|
|
|
- Hi/Low gas and low flow alarms available
- Serial output & data-logger package available
- Light-duty pre-filter & condensate removal
- Up to 6 other gases measured (depending on application)
- Cabinet cooling available
|
|
|
|
- Easily zero checked on ambient air
- On bottled SO2 in N2 gas for Span
- On bottled N2 or Air for Zero
|
|
|
|
Nova 460 / 461 analyzers are suitable for clean dry process gases only. Some gases may interfere with SO2 measurement; complete information on sample gas composition is required. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova at 1-800-295-3771. In many cases, we are able to build an analyzer specific to your needs.
|
|
|
|
|
|
|
|
|
|
|
|