All Categories > Multigas Analyzers > Item # 360 Series  


Item # 360 Series, Portable Flue Gas Analyzer for Oxygen and Carbon Monoxide


The Nova 360 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. The sensors respond quickly to the oxygen and carbon monoxide (CO) present in the flue gas sample. The typical sensor life expectancy is between 3-4 years and they are customer-replaceable.

In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter and flow meter, then on to the three sensors. The detected O2 and CO are displayed on separate LCD digital meters, which have a switchable backlight for use in dark areas. A special water separating filter and separate drain pump continuously remove condensate fro teh sample so the analyzer can be operated fro long periods unattended.

The Nova 360T indicates net stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.

A rechargeable 'gel cell' battery provides enough power for about 16 hours of continuous operation and the analyzer can be used while it is being recharged. A red LED indicates when to recharge and a green LED verifies that it is receiving recharging power. The charger is included with the analyzer.  The rugged dust-tight and water resistant case is suitable for use in harsh environments.




 Specifications 

Method of Detection

Customer replaceable electrochemical O2 and CO sensors

Ranges Available

0-1800°F (0-1000°C) net stack temperature
0-25.0% O2; 0-2000 PPM to 0-4.00% CO (switch selectable)

Resolution

0.1% O2, 1 PPM CO

Accuracy & Repeatability

±1% of O2, ± 1 PPM CO

Drift

±1% of full scale per 8 hours of continuous operation

Response Time (T-90)

5-8 seconds for O2 and CO

Ambient Temperature Range

0 to 40 ºC
32 to 105
ºF

Linearity

±1% of full scale of each gas measured

Size & Weight

Suitcase (K) Style: 14" L x 10 1/2" W x 6" H @ 12 lbs (36 x 27 x 15cm @ 5.5 kg)
Weatherproof (WP) Style: 10" L x 7 1/2" H x 8" D @ 8 lbs (25 x 19 x 20 cm @ 3.6 kg)

Power

AC/DC Operation, 115 VAC 60 Hz for recharging (Other voltages available)

Output Options

4-20 mA or 0-1 VDC

Alarms

High CO alarm with LED

Unique Applications

All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

Primary Gas to be Measured

Flue Gas or Emissions

Industry Type

Steel Making



Print Back