The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the interference effects of CO, CO2, and CH4. This ensures that Hydrogen will always read correctly regardless of the background gas composition. A long life electrochemical sensor is used for PPM or % O2 analysis. In most cases, sensors are installed in a temperature controlled box to improve reading accuracy. All detected gases have a separate digital readout and linear recorder output. Various versions available for either exothermic or endothermic mixtures, or for other industrial process gases.
Unit of Measure

Specifications

Method of Detection

N/A Dielectric ceramic sensor for Dew Point Electrochemical sensor for O2 NDIR infrared detector for CO, CO2, CH4 & NH3 Thermal conductivity cell for H2

Ranges Available

N/A 0-10%, 0-100.0% CH4 0-100% NH3 0-10000 PPM, 0-50.0% O2 0-2.00%, 0-100.0% CO2 0-20.0%, 0-100.0% CO 0-40.0%, 0-100.0% H2 -10 to 80°F (-23 to 26°C), 48 to 68°F (-100 to 20°C) D.P.

Resolution

N/A 0.1%, 1 PPM, 1°F (Dew Point)

Accuracy & Repeatability

N/A ±1% of full scale on all gases

Drift

N/A Less than 2% of full scale per month

Response Time (T-90)

N/A 20-30 seconds to 90% step change

Ambient Temperature Range

N/A 32 to 122°F (0 to 50°C), Lower temperatures (-5°F, -20°C) with Cold Weather Package

Linearity

N/A ±1% of full scale

Size & Weight

N/A Physical data will vary depending on model and enclosure required

Power

N/A 115 VAC, 60 Hz 220 VAC, 50 Hz

Output Options

N/A 4-20 mA into 500 ohms non-isolated standard Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs

Alarms

N/A High and/or Low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating Low flow alarm

Unique Applications

N/A
    Special models of the 7900 Series analyzers can be supplied with options such as free standing cabinets, built-in moisture removal systems, cabinet coolers, controllers, hi/low alarms, low flow alarm, 4-20 mA outputs, recorders, etc. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.

Applications

N/A

    For continuous monitoring of any combination of heat treat atmosphere gases such as Oxygen (O2), Methane (CH4), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen (H2), Ammonia (NH3), and Dew Point (standard and low ranges). Also available for other industrial process gases.

Features

N/A

  • Best value multi-gas analyzer including hydrogen
  • Sensitive infrared detectors for CO, CO2, CH4, and NH3 temperature controlled where necessary to reduce drift
  • Thermal conductivity detector for hydrogen
  • Long life (2-5 years) electrochemical oxygen sensor, PPM and % ranges available
  • Dielectric ceramic sensor for standard or low range dew point
  • Bright digital display for each gas
  • Built in sample pump or pressure regulator
  • Microprocessor for push button calibration
  • Easy to maintain modular layout

Options

N/A

  • Hi/Low gas, low flow, and diagnostic alarms available
  • Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
  • Sample conditioning systems available for removal of moisture, acidic gas, and dust
  • Cabinet purge system available for use in hazardous areas
  • One-step 'cal-now' button with touch screen LCD display
  • Full automatic calibration with touch screen LCD display
  • Cold weather package for operation to -5°F (-20°C)
  • Cabinet coolers can be fitted to most models
  • High temperature filters and probes
  • Sensors mounted in temperature controlled heated box to improve accuracy

Calibration

N/A

  • Ambient air for O2 span and other gases zero
  • Analyzed calibration gas with representative concentrations of non-O2 gases for span