All Categories > By Industry or Application Specific Product Lines > Indoor Air Quality & Personnel Safety > Continuous Ethylene (C2H4) Alarm Monitors - 596 Series > Item # Model 596DR1  


Item # Model 596DR1, Continuous Ethylene (C2H4) Alarm Monitor, 1 remote sensor


Designed to monitor and alarm for ethylene (C2H4) levels in ambient air near agricultural sites, food & fruit storage, and controlled atmosphere storage, etc. The ethylene sensor is of the disposable electrochemical type with an expected life of between 3-4 years. The sensor needs no warm up time and is ready to go as soon as the monitor is turned on.

Model 596DR1 has one remote sensor which is electrically connected to the main cabinet.







Specifications  · Applications  · Features  · Options  · Unique Applications

Specifications

Method of Detection

Disposable electrochemical cell

Ranges Available

0-20 PPM standard

Resolution

1 PPM

Accuracy & Repeatability

±1% of full scale or 1 PPM, whichever is higher

Drift

Less than 1% of full scale or 2 PPM per week, whichever is greater

Response Time (T-90)

Less than 15 seconds to 90% step change

Ambient Temperature Range

32 to 120°F (0 to 40°C), may be operated at lower temperature with auxiliary heater

Linearity

±1% of full scale or 1 PPM, which ever is higher

Size & Weight

14" H x 12" W x 8" D (35.6 x 30.5 x 20.3 cm) @ 18 lbs. (8.2 kg)

Power

115 VAC, 60 Hz
220 VAC, 50 Hz

Output Options

0-1 VDC
4-20 mA

Alarms

Optional - Dual high Ethylene (C2H4) alarm light and relays (SPDT - 5A@ 230 VAC)
Optional: Audible alarm with 'Acknowledge' button


Applications
Designed to monitor and alarm for Ethylene (C2H4) levels in ambient air near industrial sites, manufacturing facilities, combustion processes, etc.



Features
  • Standard electrochemical cell
  • Fast response to the presence of Ethylene (C2H4) in the air
  • Instant warm-up, no wait
  • Bright digital readout - no reading interpretation errors
  • Easy use and calibrate
  • Easy to maintain modular layout
  • 4-20mA output signal for recording
  • NEMA 12 fiberglass enclosure is standard




Options
  • 'Fail Safe' alarms available
  • Strobe light
  • NEMA 4 or 4X enclosures
  • Cold weather package for operation to -5°F (-20°C)