Canada
270 Sherman Avenue N. Hamilton, ON L8L 6N5
Phone: (905) 545 2003• Fax: (905) 545 4248 |
United States
1925 Pine Avenue Niagara Falls, NY 14301
Phone: (716) 285-0418 • Fax: (716) 282-2937 |
|
Email: sales@nova-gas.com or websales@nova-gas.com
|
|
|
|
|
Item # Model 360K, Portable Flue Gas Analyzer for Oxygen and Carbon Monoxide, Suitcase (K) Enclosure
|
|
|
|
The Nova 360 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. The sensors respond quickly to the oxygen and carbon monoxide (CO) present in the flue gas sample. The typical sensor life expectancy is between 3-4 years and they are customer-replaceable.
In operation, a built-in sample pump draws in the flue gas sample through the S.S. probe, 12 ft. sample hose, condensate removal filter, secondary filter and flow meter, then on to the three sensors. The detected O2 and CO are displayed on a digital meter.
The Nova 360T indicates net stack temperature for doing fuel efficiency calculations. The temperature sensor is built into the sampling probe. Efficiency charts for each fuel are provided.
A rechargeable battery provides enough power for about 8 hours of operation and the analyzer can be used while it is being recharged. Recharger is included with the analyzer.
|
|
|
|
|
|
|
2
) and carbon monoxide (CO). For checking combustion efficiency, air infiltration, and burner & control performance of furnaces, heaters and boilers. May be used in commercial, industrial and residential settings.
|
|
|
|
- Rugged design that is easy to operate and maintain
- Fast warm-up and response
- Digital readout meter
- Rechargeable battery operation
- Built in pump, filter, flow meter, and continuous condensate removal
- Suitcase cabinet (K) is weatherproof when closed
- Stainless steel probe with sample hose
- For use on any fuel
- Long life detector cells for O2 and CO (customer replaceable)
- Rapid CO reading recovery on CO 'overdose'
- Pays for itself in months through fuel savings
|
|
|
|
- Recorder output - 4-20mA
- stack temperature readout (360T)
- Special sampling probes
- Sample pre-cooler
- Suitcase (K) style cabinet available
- Data-logging to USB stick
|
|
|
|
- Air for O2 span and CO zero
- Analyzed mixture of CO in nitrogen for CO span and O2 zero
|
|
|
|
All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.
|
|
|
|
|
|
|
|
|
|
|
|
|
|